See page 13 for ORP Probe calibration instructions.
The OxiBOSS will show the ORP Probe calibration
reminder, 12 months after the last successful
calibration.
When the peristaltic dosing pump has operated for
a total of 50 hours, the OxiBOSS will show the
squeeze tube reminder.
See page 15 for instructions on how to lubricate or
change the Squeeze Tube.
Cal Age
is the number of days since the last
successful ORP probe calibration.
Tube Age
displays how many hours the peristaltic
dosing pump has pumped sanitiser with the current
squeeze tube.
OxiBOSS DISPLAY INFORMATION
OxiBOSS DISPLAY INFORMATION
The 32 character display in your OxiBOSS provides all the information you need to help ensure that the unit is
maintaining the sanitizer level in your pool accurately, and that you know when it is time to carry out some
basic maintenance. Additionally, the OxiBOSS will warn you when it detects that something is not working as it
should. This page is a summary of the information that your OxiBOSS may display at various times.
Main OxiBOSS Display
5
The current ORP of the Pool.
The Set Point at which the OxiBOSS will
maintain the ORP level. See page 12.
The arrow is also animated whenever
the dosing pump is adding chemical.
The
Ç
Arrow here indicates that the
OxiBOSS is set to increase ORP with
sanitiser when the ORP reading is too
low.
Status Indicator
Wait
....OxiBOSS is waiting for added sanitiser to mix
into the pool before adding more, if required.
Alrm
....ORP has been below the Set Point for 4
continuous hours of operation, without ever
reaching the Set Point. See page 12.
Add
.....OxiBOSS is in Auto mode, reading is below the
Set Point, and dosing pump is adding sanitiser.
OK
.......OxiBOSS is in Auto mode, and reading is within
the Set Point. No action required at this time.
“Wait” is also displayed at start-up while the
system is waiting for the ORP to stabilise.
Cool
.....OxiBOSS has switched dosing pump off for 1
minute to cool the squeeze tube.
Off
.......OxiBOSS dosing pump is switched off. No
sanitiser will be added, regardless of reading.
See page 11.
Alarm and Reminder Messages
When the ORP reading has been below the Set
Point for 4 hours, the display alternates between
the alarm screen, and “
Alrm
” in the status, and the
beeper sounds. See page 12 for how to reset the
alarm and rectify the cause.