SAFETY INSTRUCTIONS

SAFETY INSTRUCTIONS - READ

PLEASE FOLLOW THESE IMPORTANT SAFETY INSTRUCTIONS WHEN HANDLING ANY 
CHEMICALS.

CHEMICAL SAFETY

4.  The life of the unit will be extended (as with most 

other pool equipment) if it is placed indoors or in 
an enclosed structure. This is recommended as 
sunlight can damage the Liquid Crystal Display on 
the face of the control unit. The LCD is covered 
within the warranty on a pro-rata basis.

IMPORTANT :

3.  Keep all cables and tubes visible and do not bury 

them. Also, position them so that they do not get 
damaged by lawn mowers, hedge trimmers and 
other equipment.

4. 

WARNING 

-  To  prevent  electrical  shock, 

sanitiser  spillage  or  incorrect  dosing,  replace 
damaged cords or tubes immediately.

1.  Ensure you read and follow all instructions.

CAUTION

 :

Your warranty could become invalid should you fail 
to observe the following :

3.  Turn  off  the  power  to  the  OxiBOSS  before 

replacing  the  peristaltic  dosing  pump  squeeze 
tube.

It  is  important  to  follow  basic  safety  precautions 
when installing and using this electrical equipment, 
including the following :

5.  Always  power  the  OxiBOSS  from  a  genuine 

Bionizer  power  adaptor.  An  incorrect  adaptor 
could  damage  the  OxiBOSS  and  will  void  your 
warranty.

5.  Read these instructions and keep the instruction 

manual in a safe place.

2.  Damage due to chemical spillage is not covered 

by warranty. 

2. 

WARNING 

-  Do  not  allow  children  to  use  this 

product unless they are closely supervised at all 
times. This is to prevent accidental injury.

1.  The OxiBOSS must be installed and operated as 

specified.

Liquid Chlorine does not need to be diluted for any size of pool. 

When decanting Liquid Chlorine (or any other chemical) from one container to another :

1. 

ALWAYS 

wear safety glasses and gloves.

2. 

ALWAYS 

decant chemicals in a well ventilated area, preferably outdoors if practical.

5. 

ALWAYS 

have a source of fresh water nearby, such as a hose, so you can wash down accidental spillages.

6. 

ALWAYS

  ensure  that  the  sanitiser  drum  is  BELOW  the  level  of  the  OxiBOSS  Tee,  to  ensure  that  the 

sanitiser cannot syphon from the drum to the pool when the pool pump is switched off.

7.  In case of sanitiser spillage onto clothing, eyes, skin, concrete etc, wash down with large amounts of fresh 

water immediately. SEEK MEDICAL ADVICE IF NECESSARY.

6

Summary of Contents for OxiBOSS

Page 1: ...d before you call us for advice Version 2 1a 19 Sep 2019 bionizer com au bionizer com Bionizer highly recommends that a pH BOSS automatic pH Controller is used together with the OxiBOSS Controller Whe...

Page 2: ...NG 17 BIONIZER CONTACT INFORMATION 20 CONTROL BOX INSTALLATION 9 MAINTENANCE 13 PUMP SQUEEZE TUBE LUBRICATION AND REPLACEMENT 15 TEE PIECE INSTALLATION 7 TEE PIECE HOSE INSTALLATION 10 AUTO OFF BUTTON...

Page 3: ...her load would need around 4ppM of Chlorine to maintain a chemical activity of 650 mV ORP A pool that is not being used during winter with low water temperature may need 1ppM of Chlorine to maintain t...

Page 4: ...omaticsanitisercontrol Presstoscrollthroughthesixusersettingmenus Presstosavechangeswhenadjustingsettings 16x2Linealphanumeric LCD with LED backlight Presstomakeschangestousersettings Precision high q...

Page 5: ...Main OxiBOSS Display 5 ThecurrentORPofthePool The Set Point at which the OxiBOSS will maintaintheORPlevel Seepage12 The arrow is also animated whenever thedosingpumpisaddingchemical The Arrow here ind...

Page 6: ...nd using this electrical equipment includingthefollowing 5 Always power the OxiBOSS from a genuine Bionizer power adaptor An incorrect adaptor could damage the OxiBOSS and will void your warranty 5 Re...

Page 7: ...section of pipe sufficient for the Probe Injection Tee piece For 40mm 1 5 pipe where the reducing busheswillbeused cutouta7cm 2 75 section ofpipe NOTE Turn off all valves prior to fitting the T piece...

Page 8: ...rom vertical DO NOT FIT THE TEE TO A VERTICAL PIPE AS THIS WILL MAKE THE ORP PROBE HORIZONTAL WHICH WILL RENDER THE ORP PROBE INOPERABLE Correctly Installed Tee Incorrectly Installed Tee Do not mount...

Page 9: ...resistant Any water ingress due to the unit being incorrectlymountedisnotcoveredbywarranty 1 Choose a position that will allow you to see the OxiBOSS Display easily Fix the control box in positionusi...

Page 10: ...y by hand A tool may be used for another to 1 turn if the fitting is leaking when the pumpisrunning DO NOT OVER TIGHTEN 3 After the ORP Probe is installed in the Tee piece connect plug on the ORP Prob...

Page 11: ...water This is related tobothpoolsize andpump pipesetup In general a smaller pool would use a lower Dose Setting than a large pool However other factors can affectthis suchaspoolturnovertime 20 250 000...

Page 12: ...THE SANITISER PUMP WILL BE DISABLED AND THE OxiBOSS WILL NOT PUMP MORE SANITISER UNTIL THE ALARM HAS BEEN RESET Problem DoseSettingistoolowortoohigh Fix See page 11 for information on how to changethe...

Page 13: ...rnalpowersource pleaseensurethat the pool pump is switched off and unplugged duringtheentirecalibrationprocedure The ORP Probe should be calibrated to ensure that the readout is correct Calibration is...

Page 14: ...t into the Tee Re connect the ORP Probe to OxiBOSS when done Switchyourpoolequipmentbackon Re connect the pool pump to the Bionizer power outlet or the power output to which it was connectedbeforestar...

Page 15: ...an be pushedbackinplace Pull off the pump cover Hold the top and bottom of the pump cover Lift up the pump cover fromthebottomside MAINTENANCE Apply Silicon grease here Pull out the pump rotor a littl...

Page 16: ...her lubricated or replaced the last step is to reset the Squeeze Tube remindertozero Replacement Squeeze Tubes are supplied with new Supply and Delivery tubes pre fitted for your convenience It will b...

Page 17: ...ntactyourdistributororBionizer Faulty AC DC poweradaptor FaultyOxiBOSS mainunit ReturntoBionizerforrepair ReducetheDoseSettingbyonelevelandcheckin2days DoseSettingissettoohigh Replacesqueezetubeand or...

Page 18: ...ayed when the peristaltic dosing pump has exceeded 50 hours of operation since the last time the Squeeze Tube was lubricated or changed ThismessageisdisplayedeachtimetheOxiBOSSisswitchedon If you need...

Page 19: ...s Reduces Copper Ion loss from various environmental stressors Use a double dose of Ionlife when going away for extended holidays to help ensure that you return to a pristinepool MayextendthelifeofCop...