6. Electrical Circuit
6.
03
6.3
The electrical control
In the switch cabinet there is a special control which determines the working sequence of your machine.
If the PACK-BIN is started by means of the
ON
button the machine compacts until the running time
has ended. You will find the time relay (1) for this running time in the switch cabinet. This relay covers
a time from 1 second to 100 hours.
The factory setting is 5 min. and can be changed as required.
For this the maximum period of time (1.1) is determined at first and then the percentage of this time
(1.2) is determined.
5 minutes is adjusted as follows:
The time relays (2) and (3) form parts of the extra equipment full signal. (see point 6.9.4).
Time adjustments :
(1)
Running time
time can be selected
1 sec. - 100 h.
(2)
75 % Full signal
recommended setting
3 sec.
(3)
100% Full signal
recommended setting
3 sec.