6. Electrical Circuit
6.
02
6.2
The motor overload protection
The temperature in the control cabinet should not 60°C or go below -10°C.
Where there are considerable minus temperatures, a heating element must be installed in the control
cabinet (contact manufacturer with requirements).
The motor protection switch (1) is an electronic component which switches off the machine auto-
matically in case of motor overload.
The PACK-BIN is put into operation again by turning the spindle-shaped button (2).
The adjustment of the motor protection switch depends on the rated voltage of the machine and the
efficiency of the electric motor.
The corresponding amperage is indicated on the type plate of the motor.
The motor protection switch is pre-set in the factory and the adjustment must
not be changed.