RS7580V-601 Rotary-Screw Air Compressor
33
P/N 5900090 — Rev. A — Sept. 2019
Maintenance Schedule
The following table is the Maintenance Schedule for your Compressor.
Important
: The following table is a general Maintenance Schedule based on normal usage of the
unit. Your needs may vary based on your specific environment. In general, the harsher
the environment, the more often you should perform maintenance on the Compressor.
Item
Recommended
Frequency
Comments
Cleanliness
Daily
Keep the Compressor and the area around it clean. Wipe
up any oil/lubricant spills, clean any dirt.
Oil/Lubricant level
Daily
Make sure the amount of oil/lubricant is in the normal
range. If the amount is low, add additional. If the amount
is high, drain some.
Water
Daily
Drain daily before startup.
Air pressure in Tank Daily
Make sure pressure in Tank is not leaking.
Fasteners
Weekly
Make sure the Anchor Bolts are torqued to around 55
pound feet. If too loose, tighten. If too tight, loosen.
Anti-Vibration Pads Weekly
Make sure the Anti-Vibration Pads are securely in place.
If not, adjust as necessary.
Environment
Monthly
Make sure environment is free from contamination such
as excessive dust in the air or contaminants such as
paint. Preferred environment is cool, dry, filtered air.
Belt
Monthly
Make sure the belt is tight and undamaged. Replace if
very loose or damaged.
Wiring
Twice yearly
Have an Electrician check all wiring connections inside
the Electrical Box.
Location
Yearly
The air temperature should be 41°F to 100°F (5°C to
38°C); if above or below these values on a consistent
basis, consider relocating the Compressor. The humidity
should be under 80%; if above this value on a consistent
basis, consider relocating the Compressor.
Tank
Yearly
Drain the Tank, inspect for rust and corrosion. If found,
remove. Do not attempt to repair a damaged Tank; a
damaged Tank
must
be replaced.
All components
Yearly
Take the unit out of service and professionally clean it.
Air Filter
See Comments.
The Air Filter on a new Compressor should be changed
after the first 500 hours of use and every 3000 hours
after that. More often in environments with dirty air.
Summary of Contents for RS7580V-601
Page 37: ...RS7580V 601 Rotary Screw Air Compressor 37 P N 5900090 Rev A Sept 2019 Wiring Diagram...
Page 38: ...RS7580V 601 Rotary Screw Air Compressor 38 P N 5900090 Rev A Sept 2019 Labels...
Page 39: ...RS7580V 601 Rotary Screw Air Compressor 39 P N 5900090 Rev A Sept 2019...
Page 40: ...RS7580V 601 Rotary Screw Air Compressor 40 P N 5900090 Rev A Sept 2019...
Page 43: ...RS7580V 601 Rotary Screw Air Compressor 43 P N 5900090 Rev A Sept 2019 Maintenance Log...