RS7580V-601 Rotary-Screw Air Compressor
25
P/N 5900090 — Rev. A — Sept. 2019
The three Indicators left of the Display Screen are:
•
Power
. Lightning icon, green background; glows red when the Compressor is receiving power.
•
Run
. Turning fan icon, green background; glows green when the Compressor is running.
•
Alarm
. Exclamation mark icon, red background; glows red when there is an error condition.
The Display Screen is a four-line screen that displays information about, and lets you control,
Compressor settings and operation.
The Start and Stop buttons start and stop the Compressor. The Start button starts up the
Compressor. The Stop button begins a normal stop procedure; there’s a countdown as the
Compressor goes through the steps of a coordinated shutdown. This is compared to an Emergency
Stop, where the Compressor stops immediately.
The five Buttons under the Display Screen are:
•
Set
. Saves configuration changes you have made.
•
Down
. Highlights the next option down or decreases the selected value.
•
Up
. Highlights the next option up or increases the selected value.
•
Enter
. Selects the highlighted option.
•
Back
. Returns to the previous screen.
The Emergency Stop button immediately stops the Compressor. If you press it, it stays in and the
Display Screen shows EMERGENCY STOP. Turn the Emergency Stop button to the right to disengage
it. The Display Screen changes to NORMAL STOP.
The Display Screen always shows four lines of text:
•
The top line shows the air
temperature
in the Tank.
•
The second line shows the air
pressure
in the Tank and how many volts the Compressor is pulling.
•
The third line shows the current status of the Compressor.
•
The bottom line shows the communications status of the Compressor. This feature is disabled in
the RS7580V-601, so this line can be safely ignored.
The following shows an example of what you will commonly see on the Display Screen:
Line 1:
AIR T: 150°F
Line 2:
P:140 PSI 233V
Line 3:
AUTO LOAD
Line 4:
CO1 LOCAL
Line 3, AUTO LOAD, tells you the Compressor is running at full power and adding air pressure to the
Tank, while Line 2 tells you the Tank is nearing full at 140 PSI (assuming a maximum air pressure
setting of 175 PSI).
An AUTO
UN
LOAD state means the Compressor is running at reduced power (but not off) because
the Tank is close to full; this reduces the number of start/stop cycles, extending the life of the unit.
The PSI value shown on Line 2 is the same as the pressure shown on the Air Pressure Gauge at the
top of the Tank.
Because Line 4 only ever shows communications information, and this feature is disabled, this line will
no longer be shown.
Summary of Contents for RS7580V-601
Page 37: ...RS7580V 601 Rotary Screw Air Compressor 37 P N 5900090 Rev A Sept 2019 Wiring Diagram...
Page 38: ...RS7580V 601 Rotary Screw Air Compressor 38 P N 5900090 Rev A Sept 2019 Labels...
Page 39: ...RS7580V 601 Rotary Screw Air Compressor 39 P N 5900090 Rev A Sept 2019...
Page 40: ...RS7580V 601 Rotary Screw Air Compressor 40 P N 5900090 Rev A Sept 2019...
Page 43: ...RS7580V 601 Rotary Screw Air Compressor 43 P N 5900090 Rev A Sept 2019 Maintenance Log...