RS7580V-601 Rotary-Screw Air Compressor
30
P/N 5900090 — Rev. A — Sept. 2019
Factory Parameters
Factory Parameters are the Compressor’s default settings.
Do not change any of the Factory Parameter settings unless instructed to do so by
BendPak Customer Service.
Factory Parameters are:
•
MOTOR CUR. Maximum amp draw allowed for the Compressor motor before it automatically
shuts off. Default is 038.0A.
•
FAN CUR. Maximum amp draw allowed for the Compressor fan before it automatically shuts off.
Default is 001.8A.
•
ALARM T. An alarm will sound when system temperature reaches this threshold. Default is 0221°F.
•
STOP T. Compressor stops automatically if system temperature reaches this threshold. Default is
0230°F.
•
STOP P. Compressor stops automatically if system pressure reaches this threshold. Default is
0181 PSI.
•
MAX U.L. The setting Unload Limit Pressure must be set lower than this value. Default is 0181 PSI.
•
RUN TIME. Resets the Total Run Time.
•
LOAD TIME. Resets the Total Load Time.
•
CLR FAULT. Resets the Fault History Record.
•
LOAD UN. BAL. Amount of time the Compressor waits to trigger a fault when an unbalanced load
is detected. Default is 0016S.
•
LACK PHASE. Amount of time the Compressor stops when a lack of phase is detected on the
incoming power supply legs. Default is 025.0S.
•
DATA. The date the Compressor was manufactured.
•
SERIAL. The serial number of the Compressor.
•
PHASE PRO. Toggles phase protection. Default is Off.
•
FRE. SEL. Select the power frequency. Default is 60 Hz.
•
UNLD UN. BAL. Stability threshold. The default is 0020.
•
HIGH VOL. High voltage threshold at which the Compressor shuts down. The default is 0250V.
•
LOW VOL. Low voltage threshold at which the Compressor shuts down. The default is 0190V.
•
LOW T PRO. Low temperature threshold below which the Compressor will not start. The default is
–22°F.
•
TIME LIM. If the Compressor’s Run Time value is greater than this value, the Compressor will stop
and an alarm will sound. Set to 0 to disable (which is the default).
•
ALM STOP. The amount of time an alarm can be active before the Compressor shuts down. Set to
0 to disable, which is the default.
•
COM SET PARA. Not applicable to the RS7580V-601. Default is On.
•
PARA1. The User Pin. The default is 1000.
•
PRES UNIT. Unit of measurement for pressure. PSI, MPA, and BAR are available. The default is
PSI.
•
TEMP UNIT. Unit of measurement for temperature. Celsius and Fahrenheit are available. The
default is Fahrenheit.
Calibration Parameters
Motor and Fan calibration parameters. Only accessible by BendPak Customer Service.
Summary of Contents for RS7580V-601
Page 37: ...RS7580V 601 Rotary Screw Air Compressor 37 P N 5900090 Rev A Sept 2019 Wiring Diagram...
Page 38: ...RS7580V 601 Rotary Screw Air Compressor 38 P N 5900090 Rev A Sept 2019 Labels...
Page 39: ...RS7580V 601 Rotary Screw Air Compressor 39 P N 5900090 Rev A Sept 2019...
Page 40: ...RS7580V 601 Rotary Screw Air Compressor 40 P N 5900090 Rev A Sept 2019...
Page 43: ...RS7580V 601 Rotary Screw Air Compressor 43 P N 5900090 Rev A Sept 2019 Maintenance Log...