RS7580V-601 Rotary-Screw Air Compressor
11
P/N 5900090 — Rev. A — Sept. 2019
Fuses / Circuit Breakers
. Refer to applicable local codes to determine the proper fuse or circuit
breaker rating required. When selecting fuses, remember the momentary starting current of an electric
motor is greater than its full load current. Time delay or “slow-blow” fuses are recommended.
Grounding
. In the event of an electrical short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. Ground terminals are identified with a ground symbol
and/or the letters “G”, “GR” or “PE” (Potential Earth).
Ground must be established with a grounding wire size according to the voltage and minimum branch
circuit requirements printed on the compressor specifications decal. Ensure good bare metal contact
at all grounding connection points, and ensure all connections are clean and tight.
⚠
WARNING
Improper grounding can result in electrical shock and can cause severe injury or
death. This product must be connected to a grounded, metallic, permanent wiring
system or an equipment-grounding terminal or lead. All grounding must be
performed by a qualified, licensed Electrician and must comply with all applicable
electric codes.
Summary of Contents for RS7580V-601
Page 37: ...RS7580V 601 Rotary Screw Air Compressor 37 P N 5900090 Rev A Sept 2019 Wiring Diagram...
Page 38: ...RS7580V 601 Rotary Screw Air Compressor 38 P N 5900090 Rev A Sept 2019 Labels...
Page 39: ...RS7580V 601 Rotary Screw Air Compressor 39 P N 5900090 Rev A Sept 2019...
Page 40: ...RS7580V 601 Rotary Screw Air Compressor 40 P N 5900090 Rev A Sept 2019...
Page 43: ...RS7580V 601 Rotary Screw Air Compressor 43 P N 5900090 Rev A Sept 2019 Maintenance Log...