RS7580V-601 Rotary-Screw Air Compressor
23
P/N 5900090 — Rev. A — Sept. 2019
Operation
This section describes how to operate your RS7580V-601 Air Compressor.
⚠
DANGER
When you even hear the words “air compressor,” you need to remember that being
in close proximity to one is a serious endeavor with potentially life-threatening risks.
The Compressor can start without warning. An accidental quarter turn on a ball
valve can unleash pressurized air at potentially dangerous levels. Only allow trained
personnel near the Compressor.
Do not assume you are going to be safe
this time just because nothing happened last time
.
Safety First
Before using the Compressor, do the following:
•
Check the unit
. Check the Compressor for any missing, heavily worn, or damaged parts. Do not
operate the Compressor if you find any of these issues; instead, take it out of service, then contact
, visit
, or call
(800) 253-2363
, x196.
•
Check the area
. Check the area around the Compressor for obstructions or people; anything
that might impact normal operation of the Compressor. Do not forget to check
above
the
Compressor. If you find an obstruction, move it out of the way. Do not allow anyone within 30 feet
of the Compressor while it is connected to a power source.
•
Check for safety
. Make sure everyone who is going to be walking near the Compressor is
aware of its presence and takes appropriate safety measures. Do not allow children to operate or
stay near the Compressor. Do not allow anyone under the influence of drugs or alcohol to operate
the Compressor. Only trained personnel should ever be allowed inside the Safety Exclusion Zone
or be allowed to operate the Compressor.
Anything that could impact the safety of the people in the vicinity of the Compressor
must
be fully
resolved before the Compressor can be used.
Only use the unit if it can be used safely
.
Quick Start
If your Compressor passed the Operational Test and you are willing to use default settings, getting
your Compressor up and running can be done quickly.
To quick start your Compressor
:
1.
Open the Discharge Port using the Ball Valve.
The Discharge Port should already be connected to the facility’s Air Pressure infrastructure. If it is
not, connect it, then open the Discharge Port using the Ball Valve.
2.
Check the Display Screen to make sure the Compressor is getting power.
3.
Check the oil/lubrication level; add oil if necessary.
4.
Press the Start button (
I
).
The Compressor starts up and begins pressurizing air and storing it in the Tank.
5.
Check the Display Screen; the third line down should say AUTO LOAD.
The Compressor is up and running using default settings.
Summary of Contents for RS7580V-601
Page 37: ...RS7580V 601 Rotary Screw Air Compressor 37 P N 5900090 Rev A Sept 2019 Wiring Diagram...
Page 38: ...RS7580V 601 Rotary Screw Air Compressor 38 P N 5900090 Rev A Sept 2019 Labels...
Page 39: ...RS7580V 601 Rotary Screw Air Compressor 39 P N 5900090 Rev A Sept 2019...
Page 40: ...RS7580V 601 Rotary Screw Air Compressor 40 P N 5900090 Rev A Sept 2019...
Page 43: ...RS7580V 601 Rotary Screw Air Compressor 43 P N 5900090 Rev A Sept 2019 Maintenance Log...