Section G. Maintenance Belarus– 510/512 Operating manual
94
Operation 22. Flushing hydraulic sys-
tem oil filter
NOTE:
Subsequent flushings of the
hydrualic system oil filter must be per-
formed after each 1,000 service hours.
• Unscrew the bolts (1) and remove the
cover (2), take out the filter housing
assembly (3).
• To flush the filtering elements (4),
take them out of the housing (3) by
removing the wire (5).
• Flush the elements in detergent solu-
tion and after flushing perform the op-
erations in the reverse order.
• Install the filter assembly into the hy-
draulic system tank, close it with the
cover (2) and screw the bolts (1).
Operation 23. Cleaning alternator
Clean the alternator from dust and dirt.
Check and tighten, if necessary, the alter-
nator fastening bolts (1). Check the condi-
tion and firmness of the alternator
clamped connections (2).