BELARUS-1221.2/1221
В
.2/1221.3 Operating controls and instruments
42
mode of displaying operating parameters specified below over the cycle. The faults
are displayed on the LCD each time the instrument is switched on until the fault is
eliminated.
Note:
- On switching on the power supply of the CI, the LED shows the information in the
indication mode selected until the power supply of the CI is switched off in case of
absence of the messages about faults.
1.13 Setting and Adjustment of the speed sensors (BV1, BV2) (Fig. 6)
The speed sensors (2) are fastened by means of the bolts (3) to the cover of the rear
axle housing (1) in the zone of the left and right final pinions (6) of the final drives.
The gap “S” between the end face of the sensor and projection of the tooth of the fi-
nal pinion shall be adjusted by means of the spacers (5) as follows:
1.
measure the dimension “
Н” from the surface of the cover (1) to the tooth
projection;
2.
select and place the necessary number of spacers for setting the gap “S”
corresponding to the measured value “Н” (see Table 13);
3.
install the ground wire (4) and tighten the bolts (3).
Table 13
Н,
mm
Number of spacers
(Pos. 5)
S, mm
Note
11,25-12
4
1,05-1,6
When using the cover (1) with the
thickness S=6 mm
12,1-13
3
0,8-1,8
13,1-13,73
2
0,9-1,53
13,25-14
2
1,05-1,8
When using the cover (1) with the
thickness S=8 mm
14,1-15,73
1
0,9-2,53
Fig. 6. Setting the speed sensors:
1 – cover of the rear axle cover;
2 – speed sensor (BV1, BV2);
3 – bolt;
4 – ground wire;
Summary of Contents for 1221.2
Page 1: ...BELARUS 1221 2 1221В 2 1221 3 1221 0000010РЭ OPERATORS MANUAL 2009 ...
Page 290: ...BELARUS 1221 2 1221В 2 1221 3 Supplement 293 Electrical scheme of tractor connections ...
Page 291: ...BELARUS 1221 2 1221В 2 1221 3 Supplement 294 Variants of tractor connections ...
Page 293: ...BELARUS 1221 2 1221В 2 1221 3 Supplement 290 826 3805010 instrument board scheme ...