thermo
127: Legionella
temperature
Legionella temperature not achieved within 48 hours
C
157: Boiler
Flow
Thermostat
Boiler flow overheat thermostat / safety chain open
UR
UR
C
158:
Condensate
Condensate switch of safety chain opened
UR
UR
D
164: Flow
press switch
HC
Low flow or air in system / faulty connection or water flow sensor
AR
AR
I
253:
Ambiguous err
cause
The controller is unable to identify the error cause
UR/SR UR/SR
F
257: Pack
sensor
Fault pack temp sensor
C
258: Pack
overtemp
Internal ambient temperature to high
AR
AR
C
259: CJC
sensor
Fault cold junction compensation sensor
AR
C
261: Loss of
flame Eng bu
No flame after five ignition tries in Engine
UR
E
262: Loss of fl'
Supp bu
No flame after five ignition tries in Supplementary
UR
E
263: Engi bu
BCU failure
Multiple communication request of Engine Burner Control Unit unsuccessful.
1) Failure caused by BCU
2) BCU Communication Timeout on Main Control Board
ARP
AR
F
264: Supp bu
BCU failure
Multiple communication request of Supp. Burner Control Unit unsuccessful.
1) Failure caused by BCU
2) BCU Communication Timeout on Main Control Board
ARP
AR
F
265: BCU
failure
Not supported in Main Control Board
F
266: Fan fault
Fan fault: The fan speed differs from its set point for more than 30 seconds.
SR
SR
G
267: Fan
calibration
Fan calibration error: After powerup the test threshold of 4,700 rpm was not attained.
ARP
ARP
G
268: Spool
valve fault
Feedback signal of spool valve did not reach required value within detection time
typically 60 sec.
SR
SR
H
269: Spool
valve calib
During start up the feedback signal of the spool valve did not register a correct
calibration
SR
SR
H
page 78
Error code:
Display
Description
Lockout/reset
action
Fault
Section
Eng
Sup
270: exc temp.
diff h'exch
Excessive max temperature difference across the heat exchanger during 5 minutes or
excessive limit temperature difference. If temperature difference fell below (threshold
switching differential boiler): automatic reset
when the maximum setting was exceeded immediately
when the limit value was exceeded after 10 minutes
AR
AR
AR
AR 10'
I
274: Dry fire
prot
Flow sensor did not detect at least 4 L/min within 4 mins
UR
UR
I
278: Max Temp
Rise
Maximum flow temperature rise exceeded, automatic reset after 10 minutes
AR 10'
I
280 : Inner iron
overtemp
Engine dome overtemp has operated
AR
P
281: Dyn
absorber overtr
Dynamic absorber overtravel switches have been activated
SR
P
282:
G83/ENS/G1M
G83/ENS module has detected an unhealthy mains condition
AR
P
283: Altern'
overload
Alternator overload protection thermostat has operated
SR
P
284: WCS over
temp
Water cooled seal thermostat has operated
SR
SR
J
285: Alternat SC Power monitor IC has detected a shortcircuit condition
AR
P
286: Eng head
over temp
Engine head temperature thermocouple measurement has exceeded 565 degrees C
SR
K
287: Eng head
under temp
Engine head temperature thermocouple measurement below 103 degrees C when the
CX relay is energised
AR
N
288297:
Various fault
messages
Milligrid and water cooled thermostat continuity problems
SR
K / O
298: False
flame engine
burner
Ionisation probe of engine burner detected false flame
AR
299: False
flame
supplementary
burner
Ionisation probe of supplementary burner detected false flame
AR
300: Eng head
undert SW
Engine head control temperature less than 150 degrees C when connected to the grid
UR
N
Summary of Contents for ECOGEN 24/1.0
Page 69: ...Fig 77 Fig 78 Fig 79 page 69 16 0 Schematic Wiring 16 1 Burner Control Units BCU Connections...
Page 70: ...page 70 16 2 Milligrid 24 way Connector...
Page 71: ...page 71 16 3 14 way Connector...
Page 72: ...page 72 16 4 Engine Circuit...
Page 73: ...page 73 16 5 Power Monitoring 24Vdc Power Supply...
Page 74: ...page 74 16 6 External Connections External Wiring...
Page 85: ...page 87...
Page 86: ...page 88...
Page 87: ...page 89 Section P...
Page 88: ...page 90...
Page 89: ...page 91 Section Q Engine developing less than 950W after 15 minutes running at maximum rate...
Page 91: ...page 93 page 94 page 95 page 96 MICRO CHP SYSTEM COMMISSIONING CHECKLIST...
Page 92: ...page 97...