Putting the testing system out of operation
Syscompact 2000 M pro
78 / 98
822-175-2
14.3 Taking the system out of operation
Prerequisite
The test object is discharged, grounded and short-circuited.
Procedure
NOTICE
Damage to devices due to improper use.
Do not switch off the system under load.
Before switching off the system, bring it to the
Ready for operation
operating state.
1. Switch off the IRG 2000 time domain reflectometer with the
key.
2. Switch off the system using the On/Off switch on the control panel.
3. To disconnect the system completely from the supply voltage, pull out the mains plug.
4. Press the emergency off button and remove the safety key.
5. Disconnect the connection cables in the reverse order.
Important:
Finally, disconnect the earth cable last.
6. Clean the connection cables.
7. Secure the connection cables onto the holder or clear them away.
8. If necessary, remove the cordoning.
9. Remove the earthing and the short-circuit on the test object only if no subsequent work is
required and if the test object is to be put back into operation by the responsible
individuals.
10. Remove the barriers and marking of the test area.