Troubleshooting and fault correction
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
245
9
P0208
Error encoder 1
P0209
Error encoder 2
Error No.
Meaning
Reaction
Troubleshooting
112
Communication error encoder 1
IS
See
Error encoder 1 - serial interface Error encoder 2
113
reserved
114
Error at overwriting of
encoder position information
IS
Execute the command again. If the error occurs again,
contact Baumüller Nürnberg GmbH.
115
Cable break encoder 1
IS
Remove the cable break in the encoder cable of
encoder 1 or check the assignment of encoder cable
116
Overspeed encoder 1
IS
Check the allowable rotational speed for encoder 1
117
Amplitude limit exceeded
IS
Check the encoder cable and the encoder function.
Use a different encoder
118
Encoder type unknown
IS
Check if the correct encoder is connected or use
another encoder
119
Invalid data field for motor data
IS
Use another encoder
120
Incorrect motor data
IS
121
Saving error of motor data
IS
122
Motor data write-protected
IS
123
Field angle error
IS
Check the shielding of the encoder cable
124
Encoder without temperature measuring
adjustable Use an encoder module with temperature sensor
125
Memory capacity in the encoder for electronic
type plate too small
adjustable Use another encoder with a greater memory
126 to 127
reserved, not assigned = 0
Error No.
Meaning
Reaction
Troubleshooting
128
Communication error encoder 2
IS
Error encoder 1 - serial interface Error encoder 2
129
reserved
130
Error at overwriting of
encoder position information
IS
Execute the command again. If the error occurs again,
contact Baumüller Nürnberg GmbH.
131
Cable break encoder 2
IS
Remove the cable break in the encoder cable of
encoder 2 or check the assignment of encoder cable
132
Overspeed encoder 2
IS
Check the allowable rotational speed for encoder 2
133
Amplitude limit exceeded
IS
Check the encoder cable and the encoder function.
Use a different encoder
134
Encoder type unknown
IS
Check if the correct encoder is connected or use
another encoder
135
Invalid data field for motor data
IS
Use another encoder
136
Incorrect motor data
IS
137
Saving error of motor data
IS
138
Motor data write-protected
IS
139
Field angle error
IS
Check the shielding of the encoder cable
140
Encoder without temperature measuring
adjustable Use an encoder module with temperature sensor
141
Memory capacity in the encoder for electronic
type plate too small
adjustable Use another encoder with a greater memory
142 to 143
reserved, not assigned = 0