Controller terminals
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
220
7.11
7.11.3 Digital inputs slot A to E/position D
Figure 96:
Skinning length
NOTE!
The module DIO/FIO can used
only
in position D of ES controller.
The module BM4-F-DIO/FIO can be used in all slots of the standard controller, but
preferred should be slot D.
NOTE!
Further information referring to digital inputs/outputs, see manual
BM4-F-DIO/FIO
(5.01046).
Pin assignment
Pin No.
Pin assignment
Multi-pin connector 10-pin
1
IN 1
2
IN 2
3
IN 3
4
IN 4
5
OUT 1
6
OUT 2
7
OUT 3
8
OUT 4
9
+24 V
10
M 24 V
Max. cross-section
of connection
Connection technology
1.5 mm
2
Connector, 10-pin