Baumüller accessories
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
Baumüller Nürnberg GmbH
310
11.5
Use the instructions stated below, in order to make the cable self:´´
1
Use the following materials:
m
Cable: 14 wires (recommendation: 6 x (2 x 0.14mm
2
) + 2 x 0.5 mm
2
), twisted pairs,
pairs layer-twisted, tinned Cu transfer, Cu braiding with at least 85% opt. overlap.
m
D-sub connector. 15-pin, male
m
Circular connector: 17-pin, female (e. g. Interconnectron)
2
connect the cable shield laminar with the shield of the D-sub connector.
Figure 110:
Cable connector for sine-cosine encoder with EnDat
®
-interface
NOTE
The cable connector must be produced according to the illustration which is shown
above!
In case there is another assignment of the pins, the cable will not operate and defects
as well as at the encoder module and also at the encoder can appear!