7.9
8
Connect encoder(s) (for further information, refer to handbook encoder modules,
5.01042).
9
Connect the temperature sensor of the motor. (Observe the proper polarity!)
10
Connect the signal generator for the pulse enable:
terminals X3-5, X3-3
11
Connect the signal generator for the quick stop:
terminals X3-4, X3-3
12
Perhaps connect (dependent on the application -
not necessary for power modules
- a brake resistor (R
B
) via terminals Ba+, Ba-.
13
Connect the brake of the motor (option):
Terminals X101-1/2 and X101-3/4
14
Connect the safety relay (if existing) via X102-3 and X102-4 as well as X103-3 and
X103-4 (connection data safety relay also see
C.5 Technical data safety relay mod-
NOTE!
Plugging in and pulling out encoder cables while they are energized is prohibited, and
could lead to their destruction.
Therefore, always first switch off the 24 V supply voltage and lock the encoder con-
nectors when operating.