Troubleshooting and fault correction
Instruction handbook
b maXX
BM4400, BM4600, BM4700
Document No.: 5.12008.07
251
9
P0234
P0235
Error encoder 1 - serial interface
Error encoder 2 - serial interface
Error encoder 1 112: Communication error encoder 1
Error encoder 2 128: Communication error encoder 2
Error code
Meaning
Troubleshooting
1
Analog signals out of range
Check the encoder cable and the encoder connection
2
Error internal angle offset
3
Table data field partitioning destroyed
4
Analog limits not available
5
Internal I
2
C-bus not operative
6
Internal checksum error
7
Internal watchdog error - encoder reset
8
Overflow of the counter
9
Parity error
10
Checksum error
11
Unknown error code
12
Data number error
13
Invalid argument
14
Data field is write protected
15
Invalid access code
16
Data field is not changeable in its size
17
Word address outside of data field
18
Data field is available
19 to 27
reserved
28
Absolute monitoring of the analog signals
Check the encoder cable and the encoder connection
29
Transmission current critical
30
Encoder temperature critical
Check motor temperature
31
Speed too high - no position generation possible Check the encoder cable and the encoder connection
32
Position singleturn unreliable
Internal encoder error
Contact Baumüller Nürnberg GmbH
33
Multiturn position error
34
Multiturn position error
35
Multiturn position error
36
Incorrect motor temperature check sum
Check the encoder cable and the encoder connection
37
No response from encoder
38
Encoder address unknown
39
Error reading the absolute angle position
40
Invalid checksum of received data
41
Unknown encoder type
42 to 63
reserved
64
No response of Hiperface® encoder
Check the encoder cable and the encoder connection
65
No response of Hiperface® encoder
66
Undefined response to encoder command
67
Encoder type not accepted
Use another encoder type
68 to 79
reserved