Troubleshooting and Fault correction
Instruction handbook
b maXX
5800
Document No. 5.16027.04
133
10
Position
controller
This monitoring function checks the position deviation limit statically/dynamically. If the
current position deviation is statically/dynamically larger than the set position deviation
limit, then the error message „Static position deviation“ or, respectively, „Dynamic posi-
tion deviation“ is generated. After the monitoring period (position deviation period) has
ended, an additional error message is generated and pulses are inhibited immediately.
The reaction time can be set.
Blocking
monitoring
This monitoring function checks the motor speed and the motor current.
If the following two conditions are met for at least the „Blocking monitoring interval“, then
the error message „Drive blocked“ is generated by the controller and the pulses are inhib-
ited immediately.
m
Motor speed = 0
m
The motor current output by the device is the same as the set maximal motor current
(current limit).
10.3 Error detection
LED
The error state is signalized by the lighting up of the red LED on the front side of the hous-
ing.
The meaning of the individual LEDs is explained in
Essentially, the red LEDs „Malfunction“ are of significance here.
NOTE!
In case of warnings or errors without error reactions, the red LEDs
blink
„Malfunc-
tion“. Only error messages with error reaction are signalized by
constant lighting
up
.