Requirements for the motor temperature sensors
Instruction handbook
b maXX
5800
Document No. 5.16027.04
Baumüller Nürnberg GmbH
84
7.9
Locking torque of the fixing screw:
7.9
Requirements for the motor temperature sensors
Type
Additional requirements:
Isolation
KTY84
-
SELV/PELV
PT1000
-
SELV/PELV
MSKL
1)
(PTC)
R = 1 k
at T
Schutz
, I
max
< 2 mA
SELV/PELV
To protect the motor against impermissible overheating, a motor temperature sensor can
be connected to the
b maXX
device. The device switches off of the motor when a settable
threshold temperature has been exceeded.
1)
Motor protection thermistor (PTC) as per DIN 44080-082
Axis module 1 / 2 / 3
BM5807-
S
G
Locking torque
-
22
XXXX-,
-
23
XXXX-,
-
24
XXXX-,
-
25
XXXX-,
-
26
XXXX-,
-
27
XXXX-,
-
28
XXXX-
0.8 Nm
cable diameter 5 - 20 mm
shielding clamp width 24 mm
-
31
XXXX-,
-
32
XXXX-,
-
33
XXXX-
1 Nm
cable diameter 5 - 28 mm
shielding clamp width 31 mm
NOTE!
The motor temperature sensor should be installed in such a manner that „electrically
protective separation“ is ensured. The motor temperature sensors integrated into
Baumüller motors meet these requirements. If third-party motors are connected, the
operating company must ensure that the temperature sensors used in the motor of a
third-party manufacturer motor comply with the „electrically protective separation“
function.