Technical data
Instruction handbook
b maXX
5800
Document No. 5.16027.04
39
3
Footnotes refer to
.
BM5807-
S
G
-
26
XXXX-
BM5807-
A
G
-
26
XXXX-
BM5807-
S
G
-
27
XXXX-
BM5807-
A
G
-
27
XXXX-
BM5807-
S
G
-
28
XXXX-
BM5807-
A
G
-
28
XXXX-
Input rated power
1)
6.7 kW
11.2 kW
16.8 kW
DC link voltage (U
DC
)
1)
60 V - 760 V
DC link capacity (internal)
165 µF
330 µF
495 µF
DC link discharge time (internal DC link
capacity)
120 s
240 s
450 s
Output voltage
(U
AC
)
1) 3)
0 - 500 V
Output frequency at 4 kHz
4)
0 - 450 Hz
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
4 kHz
4)
12 A
20 A
30 A
28 A at UL
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
8 kHz
4)
8.4 A
14 A
21 A
Output rated current
(I
AC
RMS)
1) 2) 5)11)
at
16 kHz
4)
4.8 A
8 A
12 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
4 kHz
4)
24 A
40 A
60 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
8 kHz
4)
16.8 A
28 A
42 A
Output peak current
(I
AC
RMS)
1) 5) 6)11)
at
16 kHz
4)
9.6 A
16 A
24 A
Short-time operation KB
200 %
Max. length of time peak current
6)
Refer to
Load cycle according EN61800-6
Power loss with regard to power supply
Max. 105 W
Max. 155 W
Max. 230 W
Power loss with regard to control voltage
supply
7)
Max. 40 W
Max. 45 W
Current of the integrated brake control
(option)
8)
Max. 2.0 A
12)
Cooling air requirement power heat sink
10 m
3
/h
-
20 m
3
/h
-
35 m
3
/h
-
Cooling air velocity power heat sink
-
> 5 m/s
-
> 5 m/s
-
> 5 m/s
Cooling air requirement internal space of
device
10 m
3
/h
-
10 m
3
/h
-
10 m
3