NMT-Master: with the NMT-command :=1 into the state „OPERATIONAL change“,
then the cyclic communication starts.
Testing of the CANopen
®
-Slave
The CANopen
®
slave is tested, by using the total CANopen
®
network.
ProDrive does not indicate errors, the CANopen
®
slave was commissioned.
Operation
m
Ensure, that the NMT master does not execute a reset, as long as the
b maXX 5800
device is in the cyclical operation
m
Ensure, that the CANopen
®
communication source only is able to communicate
with the
b maXX 5800
device.
Avoid a reset of the
b maXX 5800
in the cyclical operation of the CANopen
®
slave.
WARNING!
Risk of injury due to moving parts!
Rotating and/or linearly moving parts can cause
severe injuries.
If a reset of the
b maXX 5800
device is released in the running cyclical operation or
if the communication source is switched off, this can cause unwanted conditions in
the active application.
Therefore:
NOTE!
After a reset the booting data set is loaded in the controller. In addition the mapping
is set on the CANopen
®
, which was saved in the controller part before the reset was
executed.