Operation
Instruction handbook
b maXX
5800
Document No. 5.16027.04
111
8
8.1.2
Safety levels and safety notes
Type code
BM5800
with safety function STO (Safe Torque Off):
BM58XX-XX-XXXX
X
X-XXXX
X
X-XXXX
X
X-XXX-XXXX-XXXX-XX
Safety function option:
-XXXX
1
X-
Safety function STO
according EN ISO 13849-1 and EN 62061
Die Baumüller axis modules with type code
-XXXX
1
X-
provides the safety function STO (Safe Torque Off).
m
The drive is without torque in STO function.
m
The activation of the power amplifier is reliable disabled.
m
The STO function fulfills the stop category 0 according EN 60204-1.
If no load is active on the motor shaft, the drive will coast to a standstill. For this reason
no active danger is caused by the drive in case of an enabled STO function. A restart of
the drive is not possible without a reset of the STO function.
NOTE!
Devices with the approval mark of TÜV Rheinland and the Safety label provide a cer-
tified safety function, only, refer to
).