Technical Data
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
45
3
3.4.7
Load cycle according to EN61800-6
Operation with
constant load
Figure 14:
Typical current-time-diagram: Operation at constant load
I
b
at 2 kHz
I
b
at 4 kHz
I
b
at 8 kHz
I
b
at 16 kHz
BM3X01
5 A (100 % I
rated
)
5 A (100 % I
rated
)
3.5 A (70 % I
rated
)
2.5 A (50 % I
rated
)
BM3X11
10 A (100 % I
rated
)
10 A (100 % I
rated
)
7 A (70 % I
rated
)
5 A (50 % I
rated
)
Intermittent load
cycle with peak
value
Figure 15:
Typical current-time-diagram: Intermittent load cycle with peak value
t
p
t
o
+
I
rated
2
t
p
I
p
2
=
this term is valid for possible load cycles:
Example load cycles:
t
o
t
p
with I
p
= 150 % I
rated
t
p
with I
p
= 200 % I
rated
BM3X01
180 s
95 s (I
p
=7.5 A)
55 s (I
p
=10 A)
Summary of Contents for b maXX 3000