Cables
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
186
11.1
11.1.10.2 Connecting cable for encoder with HIPERFACE
®
.
The connecting cable is available as accessory part from Baumüller Nürnberg GmbH.
Follow the instructions below if a self-made cable is to be used:
1
Utilize the following materials:
m
Cable: Li9YC3x2x0.25-Li9Y3x2x0,25-Li9Y C11Y 1x2x0.34GN. Two cable pairs are
not needed and also not connected.
m
High-density D-sub connector: 26-pin, male
m
Round connector: 12-pin, female (e.g. from Interconnectron)
2
Fully adjoin the cable shield with the housing of the round connector and with the
shielding of the D-sub connector.
Figure 71:
Connecting cable for encoder with HIPERFACE
®
5000_1
102_rev01_int.cdr
2
1
4
5
6
19
20
17
18
7
12
10
8
1
5
2
7
3
4
6
Æ
0.34 mm
Æ
0.34 mm
NOTE
The connecting cable must be made according to the figure shown above!
If there is a different pin assignment, the cable is not operable and could lead to de-
fects, both in the encoder module and the encoder!
Summary of Contents for b maXX 3000