Connections
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
130
7.14
Encoder
evaluation with
EnDat
®
2.2
The encoders, which meet the following technical specifications, can be used:
Voltage supply
5 V
DC
controlled
Signal level
~1 V
SS
Current input
Max. 250 mA
D-sub-connector
26-pin
1
GND encoder supply
2
+5 V encoder supply
3
Clock+
4
reserved *
5
reserved *
6
reserved *
7
reserved *
8
reserved *
9
reserved *
10
reserved *
11
Sense GND
12
Sense Vcc
13
Clock-
14
reserved *
15
reserved *
16
reserved *
17
reserved *
18
reserved *
19
Data +
20
Data -
21
reserved *
22
reserved *
23
reserved *
24
reserved *
25
reserved *
26
reserved *
* do not occupy