Monitoring functions
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
172
10.2
10.2 Monitoring functions
Monitoring function
Warning/Error
Thr
esh
old
se
tt
able
Wa
rn
in
g
Wa
rn
in
g
re
act
ion
Error
Error
re
act
ion
Phase monitoring
Phase failure
-
X
2)
X
2)
Power supply failure
-
X
-
X
2)
Overcurrent Overcurrent
motor
-
-
-
X
IS
DC-link
DC-link overvoltage
-
-
-
X
IS
DC-link undervoltage
-
-
-
X
IS
Ixt-threshold
Peak current not possible, at present
-
X
-
-
-
Temperature
heat sink
Temperature > threshold 1
X
X
-
-
-
Temperature > switch-off threshold
-
-
-
X
IS
Temperature
Internal space of device
Temperature > threshold 1
X
X
-
-
-
Temperature > switch-off threshold
-
-
-
X
IS
Temperature
motor
I
2
t-threshold exceeded
-
-
-
X
IS
1)
Threshold 1 exceeded
4)
X
X
-
-
-
Threshold 2 exceeded
4)
X
X
-
-
-
Short-circuit sensor / T < 30 °C
4)
-
-
-
X
IS
1)
Sensor is not connected / T > 250 °C
4)
-
-
-
X
IS
1)
Maximum temperature exceeded
2)
X
-
-
X
IS
1)
Position controller
Position deviation error, dynamic mode
X
-
-
X
-
Position deviation error, static mode
X
-
-
X
-
Controller synchronization Controller not synchronous with external signal
-
X
-
X
1)
Encoder
Overspeed
X
-
-
X
IS
3)
Cyclic set value transmis-
sion to the fieldbus
Time-out at transmission
X
-
-
X
1)
Block monitoring
Drive blocked
-
-
-
X
IS
Signal bus
Power supply ready
-
-
-
X
1)
1)
Monitoring can be switched-off
2)
Time/operation until pulse inhibit can be set
3)
Threshold can be set
4)
Only, if a KTY/PT1000-sensor is used
IS: Pulse inhibit
X: implemented
-: not possible