Operation
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
149
8
8.3
Operating concept BM3200, BM3300
After the device was put into operation, it is parameterized (adapted to the application). If
the parameterization is completed the device can be operated either with the pulse en-
able signal or with pulse enable signal and quick stop signal.
8.3.1
Enable signals
These signals must have a signal level of 24 V
DC
and must be connected to the terminals
(
on page 121), also see
Pulse enable
During operation the signal „Pulse enable“ always must be activated, so that the device
can supply power. A running motor coasts down, if the signal is set to 0 V.
Quick stop
(optional)
Only switch off the „quick stop“ signal if the system / the device must be stopped as quick-
ly as possible, the drive reaction can be adjusted (see the parameter manual)
During operation, the „quick stop“ signal must be continuously provided in order for the
device to provide output.
Which digital input is used a quick stop input can be parameterized (see parameter man-
ual
b maXX
3000,
5.12001).
8.3.2
Monitoring
The controller part monitors the device during operation. If the controller part detects a
condition, which deviates from normal operation, the device generates a warning/an error
message.
Warning
If the controller part detects an operational condition, which exceeds a warning limit, an
according warning is either shown by the display or by the control. The device shows the
most important warning (current limit reached) via the LED H13 (see
erating elements BM3200, BM3300
Error message
If the controller part detects, that the device is not operating correctly, this is shown via
the 7-segment-display, see
and the LEDs H11 to H14, see
.
For further information see