Connecting diagrams
Instruction handbook
b maXX
BM3000, BM3200, BM3300
Document no. 5.11018.11
Baumüller Nürnberg GmbH
98
7.12
8
Connection temperature sensor of motor (consider polarity!)
m
with encoder cable
m
with plug
9
Connect signal generator for pulse enable:
via terminals X2 -5 (IF1), X2 -1 (M24V),
see
10 Only
when using devices without internal ballast resistor
BM3XXX
-XXXX-XXXXX-
E
-
XXXXX and dependent on the application connect a ballast resistor (R
B
) to the termi-
nals 1C1 and Ba-, also see
7.12 Connecting diagrams
The connecting diagram for the power supply, the motor, the pulse enable a. s. o. are
shown from
onwards.
The connection data and the pin assignments are found from
onwards.
NOTE!
The motor temperature sensor must be connected
either
on the
BM3200, BM3300
directly
or
via the encoder cable, the other input must not be connected.
NOTE!
The ballast resistor connection is not short-circuit proof.
When using devices
BM3200, BM3300
without internal ballast resistor
an external
ballast resistor must be connected in case of braking operation.
NOTE!
In order to ensure an adequate current carrying capacity of the connections, comply
to the torques!
NOTE!
The identifiers 1C1 and 1D1 were taken over from DIN EN 60445. 1C1 is the connec-
tion to the positive DC link cable/rail, and in the past was identified by Baumüller in
some devices as ZK+. 1D1 is the connection to the negative DC link cable/rail, and
in the past was identified by Baumüller in some devices as ZK-.
Summary of Contents for b maXX 3000
Page 219: ......