290
9440300990 Rev J
Specifications
DECS-250
Style CXXXXXX
AC Input
Nominal Input ................................... 120 Vac, 50/60 Hz
Input Range ...................................... 82 to 132 Vac, 50/60 Hz
Burden .............................................. 50 VA
DC Input
Nominal Input ................................... 125 Vdc
Input Range ...................................... 90 to 150 Vdc
Burden .............................................. 30 W
Terminals
AC Input ........................................... L, N
DC Input ........................................... BATT+, BATT–
Generator and Bus Voltage Sensing
Type ................................................. 1-phase or 3-phase–3-wire
Burden .............................................. <1 VA per phase
Terminals
Generator Voltage Sensing .............. E1, E2, E3
Bus Voltage Sensing ........................ B1, B2, B3
50 Hz Sensing Voltage Nominal Input, Range
100 Vac ............................................ 90 to 110 Vac
200 Vac ............................................ 180 to 220 Vac
400 Vac ............................................ 360 to 440 Vac
60 Hz Sensing Voltage Nominal Input, Range
120 Vac ............................................ 108 to 132 Vac
240 Vac ............................................ 216 to 264 Vac
480 Vac ............................................ 432 to 528 Vac
600 Vac ............................................ 540 to 660 Vac
Generator Current Sensing
Configuration .................................... 4 inputs: A-, B-, C-phase, and cross-current compensation CT input
Type ................................................. 1-phase (B-phase), 1-phase with cross-current compensation, 3-
phase, 3-phase with cross-current compensation
Range ............................................... 1 Aac or 5 Aac nominal
Frequency ........................................ 50/60 Hz
Burden
1 Aac Sensing ............................ <5 VA
5 Aac Sensing ............................ <10 VA
Terminals
A-Phase............................................ CTA+, CTA–
B-Phase............................................ CTB+, CTB–
C-Phase ........................................... CTC+, CTC–
Cross-Current Compensation .......... CCCT+, CCCT–
Summary of Contents for DECS-250
Page 2: ......
Page 6: ...iv 9440300990 Rev J Revision History DECS 250 ...
Page 16: ...xiv 9440300990 Rev J Contents DECS 250 ...
Page 20: ...4 9440300990 Rev J Introduction DECS 250 ...
Page 28: ...12 9440300990 Rev J Power Stage DECS 250 ...
Page 32: ...16 9440300990 Rev J Voltage and Current Sensing DECS 250 ...
Page 40: ...24 9440300990 Rev J Synchronizer DECS 250 ...
Page 52: ...36 9440300990 Rev J Auxiliary Control DECS 250 ...
Page 56: ...40 9440300990 Rev J Contact Inputs and Outputs DECS 250 ...
Page 84: ...68 9440300990 Rev J Limiters DECS 250 ...
Page 114: ...98 9440300990 Rev J Power System Stabilizer DECS 250 Figure 96 PSS Parameter Settings ...
Page 124: ...108 9440300990 Rev J Stability Tuning DECS 250 ...
Page 126: ...110 9440300990 Rev J Mounting DECS 250 Figure 103 Overall and Projection Mounting Dimensions ...
Page 127: ...9440300990 Rev J 111 DECS 250 Mounting Figure 104 DECS 250 Escutcheon Plate Dimensions ...
Page 198: ...182 9440300990 Rev J Timekeeping DECS 250 ...
Page 210: ...194 9440300990 Rev J CAN Communication DECS 250 ...
Page 304: ...288 9440300990 Rev J Maintenance DECS 250 ...
Page 316: ...300 9440300990 Rev J Specifications DECS 250 ...
Page 334: ...318 9440300990 Rev J Analog Expansion Module DECS 250 ...
Page 351: ......