Freezing temperature
LLC concentration
(volume %)
Down to -10 °C (14 °F)
20 %
Down to -15 °C (5 °F)
30 %
Down to -20 °C (-4 °F)
35 %
Down to -25 °C (-13 °F)
40 %
Stop the engine, and then allow the radiator
to cool.
Open the hood.
Follow the steps below to drain the coolant.
Position a container to drain the coolant
into.
Remove the drain plug from the radiator.
1
v2x572-010
Change of Coolant_001
1
Radiator drain plug
Remove the radiator cap.
1
v2x572-001
Change of Coolant_002
1
Radiator cap
1.
2.
3.
[1]
[2]
[3]
Remove the reserve tank.
1
2
ouuoov-024
Change of Coolant_003
1
Reserve tank
2
Reserve tank cap
Open the reserve tank cap, and then drain
the coolant.
Install the reserve tank.
Clean the radiator with clean water to
remove any debris or rust.
Drain all water from the radiator.
Follow the steps below to fill with coolant.
The coolant quantity, including the reserve
tank, is 12.0 dm
3
(12.0 L).
Install the drain plug.
Supply clean water and antifreeze into the
radiator up to the radiator cap opening.
Close the radiator cap.
Supply clean water and antifreeze into the
reserve tank up to the "FULL" mark.
Close the reserve tank cap.
Start the engine, and then idle for several
minutes to bleed air from the system.
Stop the engine, and then allow the radiator
to cool.
Check if the coolant level in the reserve tank
is between "FULL" and "LOW", and then
supply coolant if necessary.
Close the hood.
[4]
[5]
4.
5.
6.
7.
[1]
[2]
[3]
[4]
[5]
8.
9.
10.
11.
Maintenance
LM3210A
Maintenance
Page 6-27
Adjustment and Replacement
Summary of Contents for LM3210A
Page 6: ...LM3210A Introduction...
Page 8: ...LM3210A Contents...
Page 14: ...LM3210A Safety Page 1 6 Safe Operating Practices...
Page 36: ...LM3210A Product Overview Page 3 20 Operation Decals...
Page 80: ...LM3210A Description of Functions Page 4 44 Engine...
Page 134: ...LM3210A Maintenance Page 6 34 Storage...
Page 166: ...LM3210A Appended Table Page 8 26 List of Fault Codes...