![Baroness LM315GG Owner'S Operating Manual Download Page 70](http://html1.mh-extra.com/html/baroness/lm315gg/lm315gg_owners-operating-manual_3976900070.webp)
Fusible Link
Fuse capacity of the fusible link is 50A.
1
1qgabk-005
Fusible Link_001
1
Fusible link
Check the Operation Status of the Relay
Mower Unit Control Relay
The relay box is located behind the seat.
This controls Up/Down of the mower unit and
Rotate/Stop of the reel cutter (cutting cylinder).
The operating condition can be checked by the
illumination of the LEDs.
3
2
1
x1d47c-001
Mower Unit Control Relay_001
Refer to the table below to check the LED
status.
Condition LED status
1
Front right up/down
cylinder
(Reel rotation)
Down
ON
Up
OFF
2
Center mower up/
down cylinder
(Before pressing
Raise/Lower switch)
Up
ON
Down
OFF
3
Center mower up/
down cylinder
(After pressing
Raise/Lower switch)
Down
ON
Up
OFF
Interlock Relay
The relay box is located under the underseat
cover.
This controls a safety device for starting/
stopping the engine.
The operating condition can be checked by the
illumination of the LEDs.
1
2
3
5
4
9bth1z-001
Interlock Relay_001
Refer to the table below to check the LED
status.
Condition LED status
1
Traveling pedal
switch
Neutral
ON
Depress
OFF
2 Parking brake switch
Pull
ON
Release
OFF
3 Seat switch
Seated
ON
Away
OFF
4 Reel rotation switch
ON
ON
OFF
OFF
5
Transmission
selector lever
LAP
ON
H
OFF
L
OFF
Removal of Mower Unit
Remove the clip which fixes the mower unit
and flexible wire.
1
l9sh2i-002
Removal of Mower Unit_001
1.
LM315GC
Maintenance
Page 5-16
Maintenance (Main Body)
Summary of Contents for LM315GG
Page 6: ...LM315GC Contents...
Page 12: ...LM315GC Safety Page 1 6 Safe Operating Practices...
Page 54: ...LM315GC Handling Instructions Page 4 34 Transporting...
Page 72: ...LM315GC Maintenance Page 5 18 Long Term Storage...
Page 73: ......