R5906150 /05
XDL
52
Note:
Only remove the shunt wires from these pins which have to be connected with an external
safety interlock device. All other shunt wires must remain in place.
Note:
Maximum two external safety interlock devices can be connected. These interlock
devices must have double pole normal open contacts. So, for normal operation of the projector
the normal open contacts are pushed into the closed state to close the circuit and thus enabling
the activation of the PSU of the lasers.
The internal master key can be extended with a single pole external master key (MK).
4.
Insert the 10 pole terminal block back in its socket. Use a small screw driver to fixate the terminal block.
5.
Insert the cable(s) in the cable tie located below the terminal block (reference 5
).
1
2
3
4
5
6
7
8
9
10
A1
A2
MK
B1
B2
3
4
5
Image 5
–
12
6.
Install the cover of the mains compartment.
5.7 Three phase power input configuration of the
projector
About the power input
The projector power input can be configured for a power supply of 200-240V / 346-415V in a Y configuration
(3W+N+PE) or for 200-240V in a Δ configuration (3W+PE). Before operating the projector, place the links in
the correct position depending on the local power supply.
For a 3W+N+PE system, 346-415V is measured between the lines, 200-240V is measured between the lines
and the neutral.
For a 3W+PE system, 200-240V is measured between the lines.
Summary of Contents for XDL
Page 1: ...ENABLING BRIGHT OUTCOMES Installation Manual XDL...
Page 30: ...R5906150 05 XDL 30 Installation process...
Page 74: ...R5906150 05 XDL 74 Pulse SFP input use cases...
Page 79: ...79 R5906150 05 XDL Dimensions A...
Page 82: ...R5906150 05 XDL 82 Glossary...
Page 86: ...R5906150 05 XDL 86 Index...
Page 87: ......