R5906150 /05
XDL
34
-
The building installation has to be provided with a circuit breaker of 25-40 A to protect the complete
unit.
•
Electrical ratings for Delta system (3W+PE):
-
The cross-sectional area of the conductors in the power supply cord shall be 6mm
2
, 8AWG.
-
The electrical rating of the XDL-4K60/75 projector is 200-240V 3W+PE 28A 50-60Hz (Δ connection).
-
The electrical rating of the XDL-4K30 projector is 200-240V 3W+PE 15A 50-60Hz (Δ connection).
-
The building installation has to be provided with a circuit breaker of 40 A to protect the complete unit.
The power cord required to connect the projector with the power net is not delivered with the projector. It is the
responsibility of the customer to provide the correct type of power cord. Take into account that the cable gland
allows a cable diameter from 11 to 21 mm.
To protect operating personnel, the National Electrical Manufacturers Association (NEMA) recommends that
the instrument panel and cabinet be grounded. In no event shall this projector be operated without an
adequate cabinet ground connection.
The AC supply must be installed by a qualified electrician in conformance to local codes. Hardware, wire sizes
and conduit types must comply with local codes.
A readily accessible disconnect device shall be incorporated externally to the equipment for removal of the
power to the equipment mains terminals.
WARNING:
Disconnect the power to the unit mains terminals and unplug power cord at UPS inlet
for removal of all power from the unit
UPS requirements
The Uninterruptible Power Supply (UPS), also known as a Continuous Power Supply (CPS), must have an
output voltage of 200-240 V at 50-60 Hz and must be capable of delivering an output current of 5,5 A. This
UPS provides only power for the electronics in the Card Cage.
The connection between the UPS unit and the UPS inlet of the projector must be done with a certified AC
power supply cord of minimum 0,75 mm² or 18 AWG and minimum 300 V.
CAUTION:
The 200
–
240V power outlet (UPS OUTLET) of the projector may not be used to provide
the UPS unit with power! The UPS OUTLET of the projector may only be used for connection to the
UPS INLET of the projector.
The XDL series projector does not have a built in UPS unit.
Projection screen
The XDL series projector performs best when the image is projected on white screen with minimum gain
(between 1 and 1.8). Very high gain screens (e.g. silver screens with gain 2.4) are not recommended.
Projector weight
Do not underestimate the weight of the XDL series projector. The XDL-4K60/75 projector weight
approximately ±240 kg (±529 lbs) without lens. The XDL-4K30 projector weight approximately ±200 kg (±440
lbs) without lens. Ensure that the pedestal on which the projector is installed is capable of supporting the
complete load of the system. To prevent personal injury a hoisting tool should be used to lift the projector.
CAUTION:
An external frame must be used to stack projectors.
4.2 Unpacking the projector
What you need to do?
Upon delivery, your projector is packed into a carton box upon a wooden/plastic pallet and secured with
banding and fastening clips. Furthermore, to provide protection during transportation, the projector is
Summary of Contents for XDL
Page 1: ...ENABLING BRIGHT OUTCOMES Installation Manual XDL...
Page 30: ...R5906150 05 XDL 30 Installation process...
Page 74: ...R5906150 05 XDL 74 Pulse SFP input use cases...
Page 79: ...79 R5906150 05 XDL Dimensions A...
Page 82: ...R5906150 05 XDL 82 Glossary...
Page 86: ...R5906150 05 XDL 86 Index...
Page 87: ......