Service Mode
8-24
5976194 BARCOCINE 9 31012002
Projector Diagnostics
What can be seen ?
A log of the last 5 failures with the run time when the failure happened is consultable in the Projector Diagnostics.
How to display the Projector Diagnostics ?
1.
Push the cursor key
é
or
ê
to highlight 'Projector diagnostics' (menu 1).
2.
Press ENTER to display the projector diagnostic menu (menu 2).
The last failure will be displayed.
3.
Use the cursor keys to scroll through the failure log.
4.
Press ENTER to switch to the voltage diagnostics (menu 3).
5.
Press EXIT to return to the projector diagnostics menu.
Select with
é
or
ê
then <ENTER>
<EXIT> to return.
SERVICE MODE
menu 1
PROJECTOR SET-UP
MEMORY MANAGEMENT
COMMON SETTINGS
I2C DIAGNOSTICS
VOLTAGE DIAGNOSTICS
PROJECTOR DIAGNOSTICS
PROJECTOR DIAGNOSTICS
menu 2
Failure nr : 2
Runtime : 180h 30 min
Projector block nr : 4
Coincidence : ON
Deflection :
OFF
SF
: yes
EHT fail :no
SF vert : n o
HD EHT : no
SF hor : n o
Fan Fail : yes
IBCL fail :no
Arrow keys to scroll,
<ENTER> to see the voltages,
<EXIT> to return.
<EXIT> to return.
VOLTAGE DIAGNOSTICS
menu 3
+17V :
16.9 Volt
-17V
:
-17.1 Volt
+9V
:
+9 Volt
+12V :
+11.9 Volt
-12V
:
-11.8 Volt
+30V :
+29.8 Volt
-40V
:
-39.8 Volt
+110V :
+110 Volt
+210V :
+209 Volt
HTHD :
-conv :
+conv :
foc_lo :
foc_hi :