DRIVE MOTOR PARAMETERS CALIBRATION (**)
Standard version
In that menu front panel, you can find following data about drive motor parameters:
description, actual value, new value you want to set, measure unit, default values minimum
and maximum settable values, actual value in percent.
You can execute following operations:
Select default value:
1. Press DEFAULT button ; NEW data fields will be automatically updated with default
value
2. Press SAVE button and confirm; both OLD data fields and first 3 parameters will be
updated
Change actual value:
Insert changed value in NEW data field (or modify one of first 3 parameters)
1. Press SAVE button and confirm; in case of good result, OLD data field is updated.
2. Otherwise an error is signaled and NEW data field (or one of first 3 par.) initial value is
restored.
Discard changes:
1. Press CANCEL button; NEW data fields will be restored with initial values
2. Press SAVE button and confirm; OLD data fields and first 3 par. are restored with initial
values
Notice:
In that menu there are other 3 parameters (Slow speed, British unit, Display
brightness) that are visualized and managed in a more user friendly way.