Programmable Safety Controller SCR P
www.bernstein.eu
- Tel: + 49 571 793 0
121
Information
Type
Data Size
Reserved
2 bits
DCD Chain OSSD Status
DCD Status
1 bit
DCD Individual Device-Specific Data
SI-RF Device
In the case of the DCD-enabled gate switch (SI-RF), the DCD Individual Device-Specific Data coming back from the SI-RF
device has the following format:
Information
Abbreviation
Data size
Safety Input Fault
EF
1 bit
reserved
--
1 bit
Sensor Not Paired
BE
1-bit
DCD Data Error
CE
1-bit
Wrong Actuator
FB
1-bit
Marginal Range
BB
1-bit
Actuator Detected
RB
1-bit
Output Error
QS
1-bit
Input 2
E2
1-bit
Input 1
E1
1-bit
Local Reset Expected
LS
1-bit
Operating Voltage Warning
UW
1-bit
Operating Voltage Error
UF
1-bit
Output 2
Q2
1-bit
Output 1
Q1
1-bit
Power Cycle Required
MF
1-bit
Fault Tolerant Outputs
MQ
1-bit
Local Reset Unit
MS
1-bit
Cascadable
RS
1-bit
High Level Coding
HC
1-bit
Teach-ins Remaining
RTP
4-bit
Device ID
--
5-bit
Range Warning Count
--
6-bit
Output Switch-off Time
--
5-bit
Number of Voltage Errors
--
8-bit
Internal Temperature
20
--
8-bit
Actuator Distance
20
--
8-bit
Supply Voltage
20
--
8-bit
Expected Company Name
--
4-bit
Received Company Name
--
4-bit
20
For conversion to Internal Temperature, Actuator Distance, and Supply Voltage, see