Programmable Safety Controller SCR P
104
www.bernstein.eu
- Tel: + 49 571 793 0
8.17
Simulation Mode
Figure 90: Simulation Mode
The
Simulation Mode
tab becomes accessible when
Simulation Mode
is clicked on the toolbar. Simulation Mode
options become available on the left side of the screen. The
Simulation Mode
tab contains view only information; you
cannot click on the output or input items in this view.
[Play/Pause] Starts the simulation time running at the specified simulation speed or
temporarily stops the simulation time.
[Single Step] Advances the simulation time at the specified step interval.
[Reset] Resets the timer to zero and the equipment to the initial stop state.
[Timer] Displays elapsed time in hours, minutes, seconds, and thousandths of a
second.
Simulation Speed
—Sets the speed of the simulation.
Note:
For DCD inputs, individual devices are not simulated, only the final output that is connected to
the SCR P input terminals is simulated (on or off).