PLC Input Assembly Instance 104 (0×68)
—112 Registers (Reset/Cancel Delay plus DCD)
This Assembly Instance is used to communicate the state of all 256 Virtual Outputs and Faults and to provide the feedback
information required to execute virtual resets and cancel delays plus communicating performance and status information
about DCD devices.
WORD #
WORD NAME
DATA TYPE
0
VO1
16-bit integer
1
VO17
16-bit integer
2
VO33
16-bit integer
3
VO49
16-bit integer
4
VO65
16-bit integer
5
VO81
16-bit integer
6
VO97
– VO112 (see
16-bit integer
7
VO113
16-bit integer
8
VO129
16-bit integer
9
VO145
16-bit integer
10
VO161
16-bit integer
11
VO177
16-bit integer
12
VO193
16-bit integer
13
VO209
16-bit integer
14
VO225
16-bit integer
15
VO241
16-bit integer
16
Fault bits for VO1
– VO16 (see
16-bit integer
17
Fault bits for VO17
16-bit integer
18
Fault bits for VO33
16-bit integer
19
Fault bits for VO49
16-bit integer
20
Fault bits for VO65
16-bit integer
21
Fault bits for VO81
16-bit integer
22
Fault bits for VO97
– VO112 (see
16-bit integer
23
Fault bits for VO113
16-bit integer
24
Fault bits for VO129
16-bit integer
25
Fault bits for VO145
16-bit integer
26
Fault bits for VO161
16-bit integer
27
Fault bits for VO177
16-bit integer
28
Fault bits for VO193
16-bit integer
29
Fault bits for VO209
16-bit integer
30
Fault bits for VO225
16-bit integer
31
Fault bits for VO241
16-bit integer
32
Virtual Reset/Cancel Delay (1
–16) Feedback [RCD Feedback
Virtual Manual Reset and Cancel Delay (RCD)
on p. 38)
16-bit integer
33
reserved
16-bit integer