Programmable Safety Controller SCR P
100
www.bernstein.eu
- Tel: + 49 571 793 0
• Configuration Name
• Configuration CRC
• Date Confirmed
• Time confirmed
• Author
• Project Name
• IP Address
• Subnet mask
• Gateway address
• Link speed and duplex mode
• MAC ID
Figure 84: Viewing System and Network Settings
Viewing and Importing Controller Data
Click
Read from Controller
to view:
•
Wiring Diagram
—Removes all other tabs and worksheets from the Software and displays only
Wiring Diagram
and
Equipment
tabs
•
Fault Log
—History of the last 10 faults
Note:
Fault Log numbering increases up to 4,294,967,295 unless the Safety Controller power
cycle is performed, in which case the numbering is reset to start at 1. Clearing the Fault Log
(either via the Software or the onboard interface) removes the log history but retains the
numbering.
•
Configuration Log
—History of up to 10 most recent configurations (only the current configuration can be viewed or
imported)
•
Module Information
Click
Import Configuration & Network Settings
to access the current Safety Controller configuration and network
settings (depends on user access rights, see or