Bandit
101
Copyright 3/19
MODEL BTC-150
245811760545 29Dec2017
Page 22
Maintenance
1. Outputs on each expansion module can be diagnosed but only when just 1 channel per pair is
energized (1-2, 3-4, 5-6, 7-8).
2. CAN communication between this output module and Controller1 (C1) is good when the CAN
LED is Green. It is also good to observe whether communication between the Display and C1 is
good. If communication between C1 and the Display is bad, virtually all maintenance
information from C1 is bogus.
3. The three numeric values listed in bubbles correspond to the dip-switch settings in the
module itself. The first number '3' sets the CAN baud rate at 250k. The next two numbers are
the node I.D. in hexadecimal, in this case 10hex (aka 16dec).
Output Modules
- If CAN is red in the Maintenance pages, communication with that module may be lost,
check wiring and fuses. The status LEDs on the module itself indicate the following:
- Left blinking green; right off: Good
- Left blinking green; right solid: no communication / loading program
- Left solid green; right solid red: module software settings may not be matched
to controller