Bandit
107
Copyright 3/19
MODEL BTC-150
245811760545 29Dec2017
Page 28
Program Notes
[CAN2RxFromDisp]
[CAN2RxFromEng]
[CAN2RxFromFlexxaire]
[CAN2Tx]
[Comm2]
[Comm3]
[HourMeters]
[KeypadA3]
[ControlEngine]
- C1 will idle Eng down for
- Hydraulic Disable
- C1 loses comm with Eng
- Lost Display and Lost Joysticks
- DPF DTC's
- Push 'Force' in Maint2-DPF
- Seat Switch
- Hyd Temp over 200 (then limit to 1600rpm)
- Hyd Temp over 220 (then limit to 1200rpm)
- AccumSw is OFF
- C1 will shutdown Eng for
- E-STOP
[ControlFans]
- reversible fan
- Hyd Cooler fans will not turn on until 5sec after Eng RPM above 500
- AC ON puts fans at 40% speed
- AC Interrupt output is fired any time fans are not Fwd
-
[ControlGate]
- HydDisable, EngRunOut, not SeatSwDelay, not MowerMode disables Gate
- PushBar Dn automatically fires Gate Dn
- Mod10h34 is Gate in Mower, Swing in Grinder
[ControlHead]
- Head Will Automatically come to a controlled stop if
- HydDisable is ON
- HydTempOver220
- EngRunOut is OFF
- SeatSwDelay is OFF
- Lost Keypad A3
- AccumSw is OFF
- Key goes OFF
- Head will come to immediate stop if EngRunOut is E-Stopped
- AntiStall is active and will reduce Cutter Head to 20% power if Eng is at full load and lugs down
to 1300rpm or less. Once Eng RPM rises back above 1600rpm, Cutter Head will resume 100%.
Summary of Contents for BTC-150
Page 7: ......
Page 14: ...Bandit 12 Copyright 3 19 MODEL BTC 150 EQUIPMENT SPECIFICATIONS EQUIPMENT SPECIFICATIONS...
Page 79: ...Bandit 77 Copyright 3 19 MODEL BTC 150 SERVICE RECORD SERVICE RECORD DATE DESCRIPTION AMOUNT...
Page 80: ...Bandit 78 Copyright 3 19 MODEL BTC 150 SERVICE RECORD SERVICE RECORD DATE DESCRIPTION AMOUNT...
Page 81: ...Bandit 79 Copyright 3 19 MODEL BTC 150 BANDIT CONTROLS Bandit Track Carrier Bandit Controls...