Instructions 67-9319
Bacharach, Inc.
Page 3-27
INJECTOR CALIBRATOR CD3
OPERATION
3.2.8 Unclamping
1. Disconnect the fuel inlet.
2. Press & hold the HOLD TO OPERATE button.
3. While holding button down, move the CLAMP/
UNCLAMP lever to UNCLAMP position and let
the hydraulic cylinder completely retract.
4. Release the HOLD TO OPERATE push-button
and allow the CLAMP/UNCLAMP lever to
return to its center position.
DD Type 8.2 Liters injectors
a. Lift the key from the injector holder slot.
b. Place the two angle spacers from the
injector holder assembly (67-8525) over the
rails between the cambox and injector.
c. Press & hold HOLD TO OPERATE button.
Gradually move the CLAMP/UNCLAMP
lever to CLAMP position to extend clamp-
ing cylinder until the injector holder butts
against the angle spacers next to cambox.
Injector will "pop" out of injector holder.
d. Repeat steps 3 & 4 again.
3.2.9 Removing Injectors & Shutting Down
1. Disconnect the fuel inlet hose from the injector
holder or manifold.
2. Remove injector & accessories from calibrator.
3. Return accessories on inside cabinet door.
4. Disconnect flowmeter tubing from discharge
head.
5. Remove discharge head & store inside cabinet.
6. Remove cam and store inside the cabinet door.
NOTE:
Discharge head and cam can be
left installed on the calibrator if desired.
7. Turn off power at On/Off Switch at lower left
side of calibrator.
8. Wipe oil spills and splashes from console and
operator’s table.
Figure 3-57. Unclamping Injectors
Figure 3-58. Unclamping DD 8.2L Injectors
3 UNCLAMP
2 HOLD TO OPERATE
4 Angle spacer
4 8.2L Injector holder
4 Key
Summary of Contents for 67-7622
Page 26: ...Page 2 8 Bacharach Inc Instructions 67 9319 INSTALLATION INJECTOR CALIBRATOR CD3 NOTES ...
Page 54: ...Page 3 28 Bacharach Inc Instructions 67 9319 OPERATION INJECTOR CALIBRATOR CD3 NOTES ...
Page 96: ...Page A 2 Bacharach Inc Instructions 67 9319 APPENDIX INJECTOR CALIBRATOR CD3 NOTES ...