Page 3-26
Bacharach, Inc.
Instructions 67-9319
OPERATION
INJECTOR CALIBRATOR CD3
Figure 3-56. Testing Injectors
Stamped
Add
Correct
Tolerance (2%)
Value
Value
72.0
+
2.5 =
74.5
73.0 - 76.0
Therefore, for a type 71 Master injector stamped as
72.0, correct delivery value (fuel output) should be
73.0-76.0 mm³/str on a Bacharach CD3 Calibrator.
From the above it follows that when calibrating
and/or checking injectors in service it is necessary
to add the above numbers to the limits given by the
manufacturer. For example:
Injector N75 (part No. 522877) has limits for the
KM Calibrator of 75 - 80 mm³/str. On the CD3 it is
necessary to add 2.5. Therefore, the new limits are
77.5 - 82.5 mm³/str.
1. Press the START MAIN DRIVE button.
NOTE:
If main drive motor won’t start,
check the pulley cover. It must be tightly
closed for the interlock safety switch to
allow the main drive motor to operate.
2. Wait until trapped air escapes from the dis-
charge head through the plastic tubing leading
to the meter. Rapid chattering indicates that
air is trapped in the tubing.
3. Check the fuel pressure on the RAIL PRES-
SURE gauge. It should be about 35 psi.
4. Set the STROKE selector on 100.
5. Press START METER on the console. The light
in the button will come on.
The MM
3
/STROKE delivery display will show
cumulative readings until 100 strokes are com-
pleted. At that time the reading will stay on until
the next update which is after 100 strokes when the
red dot will flash. Readings will be updated auto-
matically every 100 strokes.
6. Observe the LED display and record fuel output
readings.
The reading is in mm
3
/stroke, which is equivalent
to cm
3
/1000 strokes (cc/1000 strokes). During a test
run, if a change over is made from 50 to 100 stroke
setting, or vice versa, ignore the next reading
7. When the test is over, press the STOP button
on the left hand operator’s table.
1 Pulley
cover
4 Stroke
selector
5 Display of
Fuel output
7 Stop
5 Start
meter
3 Rail
pressure
1 Start
main drive
3 Rail pressure
regulator