Page 3-14
Bacharach, Inc.
Instructions 67-9319
OPERATION
INJECTOR CALIBRATOR CD3
The reading is in mm
3
/stroke, which is equivalent to
cm
3
/1000 strokes (cc/1000 strokes). During a test
run, if a change over is made from 50 to 100 stroke
setting, or vice versa, ignore the next reading
7. When the test is over, press the STOP button
on the left hand operator’s table.
3.1.9 Unclamping
1. Disconnect the fuel inlet.
2. Press and hold the HOLD TO OPERATE
button.
3. While holding the button down, move the
CLAMP/UNCLAMP lever to the UNCLAMP
position and let the hydraulic cylinder
completely retract.
4. Release the HOLD TO OPERATE push-button
and allow the CLAMP/UNCLAMP lever to
return to its center position.
5. Press the BODY TO SEAT RELEASE button,
and hold down until the BODY TO SEAT green
indicator retracts.
3.1.10
Removing Injectors & Shutting Down
1. Disconnect the fuel inlet hose from the injector
holder or manifold.
2. Remove injector and accessories from the
calibrator.
3. Replace accessories on inside cabinet door.
4. Disconnect flowmeter tubing from discharge
head.
5. Remove discharge head and store inside the
cabinet door.
6. Remove cam and store inside the cabinet door.
NOTE:
Discharge head and cam can be
left installed on the calibrator if desired.
7. Turn off power at On/Off Switch at lower left
side of calibrator.
8. Wipe oil spills and splashes from console and
operator’s table.
Figure 3-31. Unclamping Injectors
3 UNCLAMP
2 HOLD TO OPERATE
Summary of Contents for 67-7622
Page 26: ...Page 2 8 Bacharach Inc Instructions 67 9319 INSTALLATION INJECTOR CALIBRATOR CD3 NOTES ...
Page 54: ...Page 3 28 Bacharach Inc Instructions 67 9319 OPERATION INJECTOR CALIBRATOR CD3 NOTES ...
Page 96: ...Page A 2 Bacharach Inc Instructions 67 9319 APPENDIX INJECTOR CALIBRATOR CD3 NOTES ...