148
ZM400 Series Indicators Service Manual
13.12 D-cell Battery pack option (AWT05-505852) and external battery circuitry
Turn knobs counter clockwise to remove the door.
Clockwise to secure door in place.
Mounting holes for
indicator base.
Pass cable through an available gland, attach the
wires to the orange connector as described below:
Battery Connections
:
White wire to + side of TB4
Black wire to - side of TB4.
On/Off button
Open
Close
Dimensions:
9 in (22.86 cm) L
5.25 in (13.33 cm) W
2.75 in (6.98 cm) H
+
0.20A
+
ZM
Power
ZM - Output #3
+ RLY
External
Battery
Internal PC board
ZM-BAT PCB
Wire Color
Signal
ZM30x
TB2 - 1
White
+ Volt
TB4 (+)
TB2 - 2
Black
- Volt
TB4 (-)
TB3 - 1
Green
Out3 (sleep)
TB2 - 7
If you use an external battery for power and wish to take advantage of the
auto off function, follow the suggested circuit illustration below.
External battery circuit
TB3
TB2
Wiring chart