ZM400 Series Indicators Service Manual
121
4
MOTN
Motion
Motion
INTEGER
Show Sign
p
1 = Show - (default)
2 = Show +
3 = Show All
4 = Hide All
6
OVER
Overload
Overload
7
UNDER
Underload
Underload
Leading Zero
Z
0 = None (default)
1 = Leading Zeros
2 = Leading Spaces
8
CZ
Center of Zero
Center of Zero
12
CNT
Count
Count
Width
W
1 - 127 Characters
Default is Configuration Dependent
38
INMOTM
InMotion Time
InMotion Time
107
CAT
Accumulated Count Value Total
Count Total
Justification
J
1 = Right (default)
.2 = Left
250
OUT1
Output 1 State:
0 = Not Active, 1 = Active
OUT1
251
OUT2
Output 2 State:
0 = Not Active, 1 = Active
OUT2
252
OUT3
Output 3 State:
0 = Not Active, 1 = Active
OUT3
300
RTN
Transaction Count
Transaction Count
301
CON
Consecutive Number
Consecutive Number
304
B2H
Binary to Hexadecimal
Bin2Hex
Mode
(Applies to tokens
304 and 305 only)
M
1 = Stop (default)
2 = Start
305
B2A
Binary to ASCII
Bin2Asc
313
DIS
Status Byte
See
Status
Binary Output
B
1 = Truncate to 1-Byte Integer
2 = Truncate to 2-Byte Integer
3 = Truncate to 4-Byte Integer
4 = 4-Byte Floating Point
Binary Conversion
c
1 = As Binary (High Byte First)
2 = As Comma Separated Decimal in ASCII Format (High Byte First)
3 = As HEX in ASCII Format (High Byte First)
314
UTID
Unique ID (Archive menu)
DSD Consec.
302
CKSM
Checksum
Checksum
Mode
Applies to token 302 only
M
1 = Stop
2 = Transmit LSB First
3 = Transmit MSB First
4 = Send CRC 7-Bit
50 = Start CCITT
51 = Start SDLC / HDLC
52 = Start CRC 16 (0000)
53 = Start CRC 12
54 = Start IRCC 16
55 = Start IRCC 8
56 = Start Xmodem
57 = Start Sum 16
58 = Start Sum 8
59 = Start CRC 16 (FFFF)
60 = Start Inverse IRCC 8
61 = Start Sum 16 (W/O Twos)
62 = BCC
Token Token
Description of Value
Name Value
Data Type
Parameter Name
Optional Parameter
Available Values
T.x
T.x.1
T.x.2
T.x.3