Print formatting
10 Print formatting
10.1 Print Format Editor
The Print Format Editor creates custom print formats by letting you insert ASCII
characters, scale tokens and variables into a print string. See
for the ASCII characters, scale tokens and
variables that can be used.
When you use scale tokens or variables, you must append a function number to the
token or variable. The function number used depends on whether you want to print the
Value, Name or Data Type of the token. The most common function usage is to print
the token Value but in certain situations you may want to print the token Name. The
token Data Type is reserved for special application usage.
You can also append optional parameters to a token or variable to modify the default
behavior. For example, the optional parameters allow you to change the printed format
such as the number of digits or characters, or use leading zeros instead of spaces, etc.
The token that is selected will determine what optional parameters are available. See
Print tokens, parameters and default print formats
for a list of the optional
parameter tables.
The ZM series indicator also supports the UTF-8 Unicode character set which is used
for numerical HTML Coding values and to support many foreign language character
sets.
l
Following are tables showing the key functions in the string indexing and
character editing modes. Use them for reference.
After you select the index number, use the Table 2 key actions to edit the character for
that index number.
Table 1: Key Action When In The String Index Select Mode
Action
TARE
SELECT
ZERO
UNITS
F1
Momentary Key Press
Deletes current
character
Selects the index
character for editing
using the key actions in
Table 2
EXIT
Moves left one
position in the
index
Moves right
one position in
the index
Escape Edit
mode and
Abort all
changes
Long Key Press
Deletes current
character
Inserts new character
before this point.
Default character
added is 32 (space)
EXIT
Page Up
(Decrements
index by 10)
Page Down
(Increments
index by 10)
Escape Edit
mode and
Abort all
changes
Table 2: Key Action When In The Character Edit Mode
Action
TARE
SELECT
ZERO
UNITS
F1
Single Key Press
Increments the
flashing digit by
1
Decrements
the flashing
digit by 1
Enter
Delete flashing
digit
Add Digit
ESC/Abort
Long Key Press
Move flashing
digit left
Move flashing
digit right
Enter
Delete the
entire entry
Does nothing