122
ZM400 Series Indicators Service Manual
9
UNIT
Unit of Measure Type
Unit
STRING
Unit of Measure
Applies to token 9 only
U
1 = Current (default)
2 = Calibration
3 = lb
4 = kg
5 = oz
6 = g
7 = lb-oz
8 = Custom Unit 1
9 = Custom Unit 2
10 = Custom Unit 3
11 = Custom Unit 4
5
WST
Motion = M
Stable or no motion = S
sMotion
15
WSTAT
Weight Status
See
Weight Status
17
TSAT
Returns type of Tare used
See
Tare Type
28
HEX
Prints HEX value of a ASCII Decimal Value
Hexadecimal
Applies to token 28 only.
non-optional parameter
[hXX]
0 through 255
29
NCIBYTE1
Returns NCI Status Byte 1 only
See
NCI Status Byte 1
30
NCIBYTE2
Returns NCI Status Byte 2 only
See
NCI Status Byte 2
31
NCIBYTE3
Returns NCI Status Byte 3 only
See
NCI Status Byte 3
32
NCIBYTE12
Returns NCI Status Bytes 1 & 2 only
See
NCI Status Bytes 12
33
NCIBYTE23
Returns NCI Status Bytes 2 & 3 only
See
NCI Status Bytes 23
34
NCIBYTE123
Returns NCI Status Bytes 1, 2 & 3
See
NCI Status Bytes 123
309
SITE
Site ID
Site ID
310
SN
Serial Number
Serial Number
Justification
J
1 = Right (default)
2 = Left
311
LK
Condec Units = L or K
Condec Units
Width
W
1 - 127 Characters
312
STAT
Condec Status = “ “ (space = stable)
“M” = motion
“O” = out of range
Condec Status
323
S127
WI-127 Status Byte
127 Status
STATUS CODES
These are the most common characters yoiu will see on a terminal:
“0” = Valid weight
“1” = Motion
“2” = Range error (Over/Underload)
“4” = A-D error
“8” = Low voltage
Combinations of these errors can also occur. (e.g., “3 = Range error
(2) plus Motion (1))
324
NAME
Indicator Scale Name
Scale Name
32 characters max entered in Ztools under SYSTEM TAB
325
LOC
Indicator Scale Location
Scale Location
Token Token
Description of Value
Name Value
Data Type
Parameter Name
Optional Parameter
Available Values
T.x
T.x.1
T.x.2
T.x.3