62
ZM400 Series Indicators Service Manual
6
ADMIN level menus
6.4.9 Serial
SEriAL
Use this to record the serial number of the indicator. The serial number is
located on the label attached to the indicator.
6.4.10 Update
uPdAtE
Use this to set the conditions for the indicator to accept software updates
from a remote site. If connected to the internet, the indicator can accept a
software update file via FTP. The software update can be installed
manually or automatically when the file is received or on the next powerup.
MAnuAL
Choices under this are
no
and
YES
. Choose
YES
to start the
update process. Choose
no
to not do an update.
no
is the
default.
If you choose
no
, no update occurs and
MAnuAL
is
displayed. If you choose
YES
, the indicator will update and
reboot.
Auto
Choices under this are
on
,
PwruP
and
oFF
. Choose
on
(the
default setting) and the indicator will update anytime it
receives an update via FTP. Choose
PwruP
to have the
indicator auto-update on powerup if an update is available.
Choose
oFF
to turn auto-update off.
Serial
Key in 1st four
digits of indicator
serial number
Key in
last digits
Update
Manual
No
Yes
Auto
On
Off
Pwrup
Manual update selection only applies when AUTO update is disabled and only if a file
has been sent via FTP to the indicator and is waiting to update.
If
Auto
=
oFF
, the only way to update the indicator is to use the
MAnuAL
update and
select
YES
.